NSN: 5930-01-189-5239
Switches
SWITCH,PRESSURE
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
cylindrical
-
Terminal Type
connector, receptacle
-
Features Provided
internally grounded
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Media For Which Designed
gas
-
Mounting Method
line
-
Overall Length
3.700 inches nominal
-
Contact Load Current Rating
250.0 milliamperes resistive load single voltage
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 300.0 deg fahrenheit maximum
-
Proof Pressure
185.00 pounds per square inch gage
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Pressure Switch Type
gage
-
Outside Diameter
0.560 inches nominal single connection
-
Pressure Connector Type
shoulder, unthreaded external single connection
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Contact Stimulus Rating
26.00 actuation point nominal pounds per square inch gage and 23.00 deactuation point nominal pounds per square inch gage
-
Overall Diameter
1.120 inches nominal
-
Sensing Element Burst Pressure
250.00 pounds per square inch gage
-
Contact Action Stimulus
increase