NSN: 5930-01-312-5601
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Special Features
terminals 5.500 in. lg
-
Hazardous Locations/Environmental Protection
vibration resistant
-
Contact Load Current Rating
1.0 amperes inductive load second voltage and 2.0 amperes resistive load second voltage and 1.0 amperes lamp load second voltage
-
Overall Length
1.040 inches maximum
-
Body Diameter
0.660 inches maximum
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Style Designator
disc
-
Distance Between Mounting Facility Centers
0.937 inches minimum and 0.999 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Mounting Method
bracket and slot
-
Features Provided
hermetically sealed case
-
Contact Stimulus Rating
125.00 deactuation point minimum degrees fahrenheit and 130.00 actuation point nominal degrees fahrenheit and 128.00 deactuation point maximum degrees fahrenheit
-
Temp Sensing Element Type
internal sensor
-
Overall Height
0.360 inches maximum
-
Mounting Slot Width
0.140 inches nominal
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Frequency In Hertz
60.0 first voltage
-
Contact Load Current Rating
2.0 amperes resistive load first voltage and 1.5 amperes inductive load first voltage and 0.5 amperes lamp load first voltage
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Terminal Type
wire lead
-
Mounting Facility Pattern
two position in-line
-
Operating Temp Rating
-10.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum
-
Contact Action Stimulus
increase