NSN: 5930-01-566-2942
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustability
actuation point adjustable
-
Nonpile-Up Contact Arrangement
1 pole, double throw, double break/double make, permanent jumper, both positions maintained
-
Contact Voltage Rating In Volts
480.0 ac at sea level third voltage
-
Contact Voltage Rating In Volts
240.0 ac at sea level second voltage
-
Style Designator
cylindrical w/port
-
Contact Adjustment Range
+175.00/+290.00 actuation point degrees celsius and +350.00/+550.00 actuation point degrees fahrenheit
-
Contact Load Current Rating
15.0 amperes resistive load first voltage
-
Contact Voltage Rating In Volts
240.0 dc at sea level fifth voltage
-
Capillary Tube Length
72.0 inches maximum
-
End Item Identification
knolls atomic power lab-special project management system
-
Part Name Assigned By Controlling Agency
temperature switch
-
Contact Load Current Rating
15.0 amperes resistive load second voltage
-
Contact Voltage Rating In Volts
120.0 ac at sea level first voltage
-
Contact Load Current Rating
0.5 amperes resistive load fourth voltage
-
Contact Adjustment Type
external actuation point knob
-
Overall Length
7.015 inches nominal
-
Terminal Type
screw
-
Contact Load Current Rating
0.2 amperes resistive load fifth voltage
-
Media For Which Designed
gas or liquid
-
Overall Height
2.250 inches nominal
-
Temp Sensing Element Type
bourdon tube or capillary tube
-
Contact Load Current Rating
15.0 amperes resistive load third voltage
-
Body Diameter
6.015 inches nominal
-
Contact Voltage Rating In Volts
120.0 dc at sea level fourth voltage
-
Mounting Method
bracket
-
Contact Action Stimulus
increase