NSN: 5945-00-115-7213

Relays and Solenoids

RELAY,ELECTROMAGNETIC

5945 - Relays and Solenoids

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.844 inches nominal single mounting facility

  • Fragility Factor

    moderately rugged

  • Overall Width

    0.700 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    800.0 milliamperes ac lamp load and 800.0 milliamperes dc lamp load

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Terminal Type And Quantity

    10 pin all functions

  • ~1

    data on certain environmental and performance

  • Storage Type

    general purpose warehouse

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Main Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Environmental Protection

    hermetic

  • Arc Quenching Method

    air

  • Unthreaded Mounting Hole Diameter

    0.147 inches nominal single mounting facility

  • Specification/Standard Data

    96906-ms25455 government standard

  • Winding Quantity

    2

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Coil Quantity

    2

  • Overall Height

    2.094 inches nominal

  • Purpose For Which Designed

    general

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Cubic Measure

    3.206 cubic inches

  • Overall Length

    2.187 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    1.5 amperes ac motor load and 1.5 amperes dc motor load

  • Duty Type

    continuous

  • Mounting Facility Pattern

    in-line single mounting facility

  • Features Provided

    polarized and latching contacts

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.