NSN: 5945-00-619-3539
Relays and Solenoids
RELAY,METER MOVEMENT
RELAY,METER MOVEMENT
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Main Contact Current Type
dc
-
Scale Linearity
nonlinear
-
Meter Body Diameter
2.210 inches maximum
-
Scale Measurement Range
+0.0/+40.0
-
Case Material
metal
-
Reset Facility Feature
not provided
-
Scale Division Quantity
20
-
Voltage Rating
24.0 volts minimum and 125.0 volts maximum
-
Terminal Type
wire loop
-
Lock In Device Type
electromagnetic
-
Meter Movement Current Type
dc
-
Terminal Quantity
4
-
Meter Mounting Type
flush
-
Meter Depth To Mounting Flange
1.470 inches maximum
-
Main Contact Current Rating
50.0 milliamperes nominal
-
Mounting Configuration
three 0.112-40 unc-2a threaded studs spaced 120 deg apart on 1.220 in. radius
-
Meter Movement Current Range
+0.0/+40.0 milliamperes
-
Release Method
electromagnetic
-
Mounting Flange Diameter
2.800 inches maximum
-
Scale Unit Of Measure Inscription
milliamperes