Technical Characteristics
-
Fragility Factor
moderately rugged
-
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
-
Storage Type
general purpose warehouse
-
Overall Width
2.125 inches maximum
-
Cubic Measure
15.339 cubic inches
-
Winding Dc Resistance Rating
94.0 ohms nominal single winding
-
Arc Quenching Method
air
-
Specification/Standard Data
96906-ms24166 government standard
-
Winding Quantity
1
-
Case Material
metal
-
Time Delay
0.01 seconds maximum fixed release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes dc inductive load
-
Overall Height
2.625 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.188 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes dc motor load
-
Overall Length
2.750 inches maximum
-
Purpose For Which Designed
general
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes dc resistive load
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Main Contact Maximum Voltage Rating In Volts
28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes dc lamp load
-
Terminal Type And Quantity
4 threaded stud all functions
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Nonpile-Up Main Contact Arrangement
1 pole, single throw, normally open, double make, momentary action
-
Duty Type
continuous
-
Time Delay
0.02 seconds maximum fixed operate time
-
Mounting Facility Pattern
in-line single mounting facility
-
Unthreaded Mounting Hole Diameter
0.219 inches nominal single mounting facility
-
~1
data on certain environmental and performance
Related Parts by Category
Related Manufacturers
- Embraer S/A
- Genicom Corp
- Mcdonnell Douglas Helicopter Co Inc
- Communications Instruments Inc
- Drs Power & Control Technologies
- Leach Corp
- Cummins Power Generation Inc.
- Cummins Power Generation Inc.
- Oshkosh Corporation
- Leach International Corporation
- Military Specifications
- Military Specifications
- Eaton Corporation
- Military Standards
- Military Standards
- Oto Melara Spa
- Leach International Germany Gmbh
- Eads Deutschland Gmbh -Verteidigung
- Socata
- Embraer Empresa Brasileira De
- E.c.a Etablissement Central Des