NSN: 5945-01-051-1364
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
60.0 amperes ac resistive load
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.490 inches minimum single mounting facility and 2.510 inches maximum single mounting facility
-
Cubic Measure
173.382 cubic inches
-
Duty Type
continuous
-
Nonpile-Up Auxiliary Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
4.615 inches minimum single mounting facility and 4.635 inches maximum single mounting facility
-
Overall Width
4.188 inches minimum and 4.312 inches maximum
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts -80 deg fahrenheit type 4f single winding
-
Mounting Facility Pattern
triangle single mounting facility
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Mounting Slot Width
0.203 inches nominal single mounting facility
-
Winding Quantity
1
-
Arc Quenching Method
air
-
Storage Type
general purpose warehouse
-
Terminal Type And Quantity
3 screw energizing element
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
60.0 amperes ac resistive load
-
Frequency In Hertz
50.0 minimum and 60.0 maximum
-
Terminal Type And Quantity
6 tab w/screw contacts
-
Overall Length
6.375 inches minimum and 6.499 inches maximum
-
Overall Height
6.187 inches maximum
-
Fragility Factor
moderately rugged