NSN: 5945-01-124-3658
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
300.0 milliamperes ac resistive load and 2.0 amperes dc resistive load
-
Fragility Factor
moderately rugged
-
Terminal Type And Quantity
20 wire hook all functions
-
Unthreaded Mounting Hole Diameter
0.152 inches nominal single mounting facility
-
Mounting Facility Type And Quantity
2 unthreaded hole single mounting facility
-
Nonpile-Up Main Contact Arrangement
6 pole, double throw, one position momentary
-
Storage Type
general purpose warehouse
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Overall Width
1.320 inches maximum
-
Environmental Protection
hermetic
-
Arc Quenching Method
air
-
Overall Length
1.880 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes ac inductive load and 1.0 amperes dc inductive load
-
Coil Quantity
1
-
Winding Dc Resistance Rating
180.0 ohms minimum single winding and 220.0 ohms maximum single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.557 inches minimum single mounting facility and 1.567 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes ac lamp load and 100.0 milliamperes dc lamp load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-
Operating Voltage Rating And Type At Specified Temp
26.5 volts teardrop, two holes type 4f single winding
-
Nominal Operating Current Rating And Type
2.0 amperes dc single winding
-
Purpose For Which Designed
general
-
Overall Height
0.765 inches nominal