NSN: 5945-01-221-5403
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
50.0 minimum and 60.0 maximum
-
Precious Material
silver
-
Main Contact Maximum Voltage Rating In Volts
230.0 ac
-
Purpose For Which Designed
specific
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal second mounting facility
-
Overall Diameter
2.810 inches maximum
-
End Item Identification
6525-01-159-3009,field radiographic/fluoroscopic x-ray system; model 350 ii
-
Terminal Type And Quantity
4 tab w/screw energizing element
-
Overall Width
2.430 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.640 inches nominal first mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.640 inches nominal first mounting facility
-
Contact Material
silver
-
Overall Length
3.620 inches maximum
-
Coil Quantity
1
-
Precious Material And Weight
0.020 silver ounces, troy
-
Mounting Facility Pattern
in-line first mounting facility
-
Operating Voltage Rating And Type At Specified Temp
230.0 volts ac nonstandard temp all windings
-
Mounting Facility Type And Quantity
3 unthreaded hole first mounting facility
-
Special Features
relay has (12) auxiliary quick-connect terminals
-
Duty Type
continuous
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, double make, momentary action