NSN: 5945-01-465-4590
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
on certain environmental and performance req
-
Test Data Document
81349--83536 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data
-
Specification/Standard Data
81349-mil-prf-83536/10-023l government specification
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes dc resistive load and 2.5 amperes ac resistive load
-
Overall Height
1.010 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes dc motor load and 2.0 amperes ac motor load
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Winding Dc Resistance Rating
260.0 ohms minimum all windings
-
Terminal Type And Quantity
8 wire hook all functions
-
Overall Width
0.525 inches maximum
-
Coil Quantity
1
-
Special Features
dpdt, low level to 10 amp, hermetically sealed, 28 vdc coil, 3% per 10,000 failure rate, raised vertical flange mount, relay
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes dc inductive load and 8.0 amperes ac inductive load
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes dc lamp load and 15.0 amperes ac lamp load
-
Main Contact Maximum Voltage Rating In Volts
28.0 dc and 200.0 ac
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility