NSN: 5950-00-006-7160

Coils and Transformers

REACTOR

5950 - Coils and Transformers

REACTOR

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 wire lead

  • Rating Method

    electrical single component all winding

  • Winding Operating Current

    8.0 milliamperes maximum of standard range b and better drop siding single component all winding

  • Inductance Rating

    20.00 millihenries nominal single component all winding

  • Dc Resistance Rating In Ohms

    6.000 single component all winding

  • Body Outside Diameter

    0.350 inches maximum

  • Inclosure Type

    fully inclosed

  • Winding Quantity

    2 single component

  • Reliability Indicator

    not established

  • Body Length

    0.410 inches maximum

  • Mounting Method

    terminal single group

  • Frequency Rating

    1.0 kilohertz nominal single component

  • Inductance Type

    fixed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...