NSN: 5950-00-075-9301
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.748 inches nominal
-
Frequency Rating
1.0 kilohertz nominal
-
Winding Shielding Method
internal shield grounded to inclosure and core
-
Body Width
3.700 inches nominal
-
Body Height
2.756 inches nominal
-
Reliability Indicator
not established
-
Overall Length
4.724 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.614 inches nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Body Length
3.858 inches nominal
-
Inclosure Type
hermetically sealed
-
Mounting Method
flange and unthreaded hole
-
Winding Tap Location
center tap
-
Winding Operating Current
250.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Terminal Type And Quantity
7 wire lead
-
Maximum Operating Temp
65.0 deg celsius
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
1 primary and 2 secondary
-
Winding Operating Current
2.0 milliamperes ac maximum
-
Winding Operating Voltage
1.25 ac volts nominal