NSN: 5950-00-076-5570
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary and 6 secondary
-
Nominal Thread Size
0.138 inches
-
Winding Tap Location
center tap
-
Winding Operating Current
25.0 amperes dc nominal
-
Overall Width
2.375 inches maximum
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum
-
Input-Output Phase Relationship
three phase to single phase and three phase to three phase
-
Winding Shielding Method
internal shield brought out to terminal and internal shield grounded to inclosure and core
-
Body Height
4.250 inches maximum
-
Overall Length
2.750 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal
-
Winding Operating Current
7.0 milliamperes dc nominal
-
Winding Operating Current
750.0 milliamperes dc nominal
-
Special Features
1primary winding;6 secondary windings
-
Thread Series Designator
unc
-
Thread Class
2a
-
Thread Direction
right-hand
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.125 inches nominal
-
Overall Height
4.250 inches maximum
-
Inclosure Type
hermetically sealed
-
Mounting Facility Quantity
4
-
Mounting Method
threaded stud
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
13.00 dc volts nominal
-
Winding Operating Voltage
24.00 dc volts nominal
-
Winding Operating Voltage
380.00 dc volts nominal
-
Terminal Type And Quantity
20 tab,solder lug