NSN: 5950-00-087-7667
Coils and Transformers
COIL,ELECTRICAL
COIL,ELECTRICAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Quantity
1 single component
-
Reliability Indicator
not established
-
Mounting Facility Quantity
2 2nd group
-
Mounting Facility Quantity
4 1st group
-
Core Construction
laminated single component
-
Mounting Method
slot single group and unthreaded hole single group
-
Winding Operating Voltage
120.00 ac pounds per hour wet single component single winding
-
Turn Quantity
650 single component single winding
-
Terminal Type And Quantity
2 threaded stud
-
Body Width
2.400 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal single mounting facility single center group
-
Rating Method
electrical single component single winding and winding turns single component single winding
-
Inclosure Type
open
-
Body Length
2.875 inches nominal
-
Body Height
2.952 inches nominal
-
Mounting Hole Diameter
0.281 inches nominal single group
-
Winding Operating Current
585.0 milliamperes nominal b and better drop siding single component single winding
-
Mounting Slot Width
0.284 inches nominal single group
-
Winding Conductor Size
0.02257 inches american wire gage single component single winding
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.900 inches nominal single mounting facility single center group
-
Distance Between Mounting Facility Centers
1.900 inches nominal single mounting facility single center group