NSN: 5950-00-112-4470
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Terminal Type And Quantity
8 tab, solder lug
-
Mounting Hole Diameter
0.187 inches nominal single group
-
Body Width
1.343 inches maximum
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Length
2.593 inches nominal
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary and 450.00 ac volts nominal single component single primary
-
Body Height
3.093 inches maximum
-
Winding Operating Voltage
100.00 ac volts nominal single component 2nd secondary
-
Mounting Facility Quantity
2 single group
-
Winding Operating Voltage
40.00 ac volts nominal single component 1st secondary
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Current
1.0 amperes ac maximum single component single primary
-
Distance Between Mounting Facility Centers
3.125 inches nominal single mounting facility single center group