NSN: 5950-00-154-3978
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.000 inches nominal single mounting facility single center group
-
Winding Operating Current
35.0 milliamperes dc maximum single component 2nd secondary
-
Winding Operating Current
35.0 milliamperes dc maximum single component 4th secondary
-
Winding Operating Current
350.0 milliamperes dc maximum single component 1st secondary
-
Body Width
3.750 inches nominal
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
-
Body Height
4.000 inches maximum
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Frequency Rating
400.0 hertz nominal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.000 inches nominal single mounting facility single center group
-
Winding Operating Current
1.25 amperes dc maximum single component 3rd secondary
-
Body Length
3.750 inches nominal
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
115.00 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
-
Mounting Hole Diameter
0.219 inches nominal single group
-
Terminal Type And Quantity
11 tab, solder lug
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Winding Operating Voltage
1.60 ac kilovolts nominal single component 2nd secondary
-
Reliability Indicator
not established