NSN: 5950-00-174-3622
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary and 2 secondary
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.164 inches
-
Winding Operating Voltage
115.00 ac volts nominal
-
Test Data Document
10001-2326425 drawing
-
Thread Series Designator
unc
-
Reference Number Differentiating Characteristics
as differentiated by test data document
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.375 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal
-
Winding Shielding Method
internal shield grounded to inclosure and core
-
Body Length
5.000 inches nominal
-
Body Height
4.000 inches nominal
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Mounting Method
threaded stud
-
Thread Class
2a
-
Overall Height
4.620 inches nominal
-
Input-Output Phase Relationship
three phase to three phase
-
Transformer Winding Connection Type
delta-wye
-
Body Width
2.370 inches nominal
-
Maximum Operating Temp
130.0 deg celsius
-
Winding Operating Voltage
34.00 ac volts nominal
-
Terminal Type And Quantity
9 tab,solder lug