NSN: 5950-00-252-1112
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Mounting Hole Diameter
0.188 inches nominal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Length
2.718 inches maximum
-
Distance Between Mounting Facility Centers
3.125 inches nominal single mounting facility single center group
-
Mounting Method
flange and unthreaded hole single group
-
Winding Function And Quantity
1 primary and 2 secondary single component
-
Winding Operating Current
180.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Current
30.0 milliamperes ac maximum single component 2nd secondary
-
Winding Power Rating
16.5 watts single component 1st secondary
-
Winding Power Rating
9.3 watts single component 2nd secondary
-
Terminal Type And Quantity
10 wire lead
-
Manufacturers Code
06130
-
Design Control Reference
7016-002
-
Special Test Features
navord od41152
-
Winding Operating Voltage
110.00 ac volts nominal and 115.00 ac volts nominal and 120.00 ac volts nominal single component single primary
-
Mounting Facility Quantity
2 single group
-
Inclosure Type
open
-
Body Height
2.281 inches maximum
-
Body Width
2.062 inches maximum
-
Frequency Rating
60.0 hertz minimum and 400.0 hertz maximum single component
-
Reliability Indicator
not established