NSN: 5950-00-273-3960
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
176.00 ac volts nominal single component single primary and 192.00 ac volts nominal single component single primary and 200.00 ac volts nominal single component single primary
-
Overall Height
6.500 inches maximum
-
Winding Operating Voltage
21.20 ac volts minimum single component 3rd secondary and 22.20 ac volts maximum single component 3rd secondary
-
Winding Operating Current
50.0 milliamperes dc nominal single component 2nd secondary
-
Winding Operating Current
5.0 amperes dc nominal single component 1st secondary
-
Overall Width
3.125 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Winding Operating Current
2.0 amperes dc nominal single component 3rd secondary
-
Winding Operating Current
7.0 amperes dc nominal single component 4th secondary
-
Mounting Hole Diameter
0.188 inches nominal single group
-
Winding Power Rating
268.8 volts-amperes single component 4th secondary
-
Winding Operating Voltage
142.00 ac volts minimum single component 2nd secondary and 149.00 ac volts maximum single component 2nd secondary
-
Winding Operating Voltage
21.20 ac volts minimum single component 4th secondary and 22.20 ac volts maximum single component 4th secondary
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Power Rating
12.9 volts-amperes single component 2nd secondary
-
Input-Output Phase Relationship
three phase to six phase single component and three phase to three phase single component
-
Winding Tap Location (Non-Core)
err-070
-
Terminal Type And Quantity
16 tab, solder lug and 49 turret
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Operating Voltage
31.20 ac volts minimum single component 1st secondary and 32.80 ac volts maximum single component 1st secondary
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 11 secondary single component
-
Winding Power Rating
76.8 volts-amperes single component 3rd secondary
-
Mounting Method
unthreaded hole single group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Special Features
one primary and eleven secondaries
-
Reliability Indicator
not established
-
Winding Power Rating
283.7 volts-amperes single component 1st secondary
-
Transformer Winding Connection Type
wye-delta-wye
-
Overall Length
4.875 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.875 inches nominal single mounting facility single center group