Technical Characteristics

  • Winding Operating Voltage

    27.90 ac volts nominal single component 1st secondary

  • Winding Tap Location

    neutral tap single component 1st secondary

  • Winding Operating Current

    0.49 amperes ac maximum single component 1st secondary

  • Winding Operating Current

    0.49 amperes ac maximum single component 3rd secondary

  • Winding Operating Current

    0.7 amperes ac maximum single component 2nd secondary

  • Winding Operating Voltage

    9.80 ac volts nominal single component 3rd secondary

  • Special Features

    1 pri winding; 5 secd windings

  • Thread Series Designator

    unc single group

  • Terminal Type And Quantity

    22 turret

  • Winding Function And Quantity

    1 primary single component and 5 secondary

  • Body Width

    1.900 inches maximum

  • Transformer Winding Connection Type

    delta-wye

  • Input-Output Phase Relationship

    three phase to three phase single component

  • Frequency Rating

    400.0 hertz nominal single component

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.468 inches nominal single mounting facility single center group

  • Reliability Indicator

    not established

  • Thread Direction

    right-hand single group

  • Thread Class

    2b single group

  • Winding Operating Voltage

    19.00 ac volts nominal single component 2nd secondary

  • Winding Operating Voltage

    177.00 ac volts nominal single component single primary

  • Winding Operating Voltage

    10.28 ac volts nominal single component 4th secondary

  • Winding Operating Current

    0.612 amperes ac maximum single component 4th secondary

  • Winding Tap Location

    neutral tap single component 4th secondary

  • Winding Tap Location

    neutral tap single component 2nd secondary

  • Nominal Thread Size

    0.138 inches single group

  • Mounting Method

    threaded hole single group

  • Mounting Facility Quantity

    4 single group

  • Inclosure Type

    fully inclosed

  • Body Height

    1.900 inches maximum

  • Body Length

    2.150 inches maximum

  • Winding Shielding Method

    internal shield brought out to terminal single component

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.800 inches nominal single mounting facility single center group

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...