NSN: 5950-00-346-7804
Coils and Transformers
REACTOR-TRANSFORMER
REACTOR-TRANSFORMER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
fully inclosed
-
Turn Quantity
60 single component 3rd winding
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Turn Quantity
60 single component 4th winding
-
Overall Length
7.234 inches minimum and 7.265 inches maximum
-
Winding Conductor Size
0.00631 inches american wire gage single component 5th winding
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Rating Method
winding turns single component all winding
-
Winding Tap Location (Non-Core)
multiple taps w/o center tap single component single secondary
-
Distance Between Mounting Facility Centers
1.234 inches minimum 1st mounting facility single center group and 1.265 inches maximum 1st mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Mounting Facility Quantity
2 1st group
-
Mounting Facility Quantity
2 2nd group
-
Winding Conductor Size
0.03589 inches american wire gage single component 1st winding
-
Terminal Type And Quantity
16 pin
-
Winding Operating Voltage
208.00 ac pounds per hour wet single component single primary
-
Mounting Method
unthreaded hole 2nd group
-
Component Name And Quantity
5 coil and 1 transformer
-
Turn Quantity
3100 single component 5th winding
-
Winding Conductor Size
0.06408 inches american wire gage single component single secondary
-
Overall Width
4.718 inches minimum and 4.781 inches maximum
-
Turn Quantity
70 single component 1st winding
-
Turn Quantity
53 single component single secondary
-
Winding Conductor Size
0.03589 inches american wire gage single component 2nd winding
-
Mounting Method
slot 1st group
-
Cubic Measure (Non-Core)
154.9 cubic inches
-
Rating Method
winding turns single component single primary
-
Winding Conductor Size
0.03196 inches american wire gage single component 3rd winding
-
Turn Quantity
200 single component single primary
-
Rating Method
winding turns single component single secondary
-
Turn Quantity
70 single component 2nd winding
-
Distance Between Mounting Facility Centers
1.203 inches minimum 2nd mounting facility single center group and 1.234 inches maximum 2nd mounting facility single center group
-
Overall Height
4.437 inches minimum and 4.562 inches maximum
-
Winding Conductor Size
0.03589 inches american wire gage single component single primary
-
Winding Conductor Size
0.03196 inches american wire gage single component 4th winding