NSN: 5950-00-495-9504
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Direction (Non-Core)
err-070
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.188 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Thread Quantity Per Inch
32 single group
-
Mounting Method
threaded hole single group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Thread Series Designator
unf single group
-
Inclosure Type
fully inclosed
-
Body Width
3.120 inches nominal
-
Terminal Type And Quantity
10 wire hook
-
Reliability Indicator
not established
-
Body Length
4.250 inches nominal
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.188 inches nominal single mounting facility single center group
-
Body Height
2.940 inches nominal
-
Nominal Thread Size
0.190 inches single group