NSN: 5950-00-497-8949
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
80070-17-13045 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Current
2.0 amperes dc maximum single component 1st secondary
-
Winding Operating Voltage
56.00 dc volts nominal single component 1st secondary
-
Winding Function And Quantity
1 primary single component and 6 secondary single component
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Winding Operating Voltage
15.00 dc volts nominal single component 4th secondary
-
Terminal Type And Quantity
24 solder stud
-
Winding Operating Current
450.0 milliamperes dc maximum single component 4th secondary
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Body Width
2.250 inches minimum and 2.375 inches maximum
-
Body Length
2.625 inches minimum and 2.750 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.734 inches minimum single mounting facility single center group and 1.766 inches maximum single mounting facility single center group
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Current
2.0 amperes dc maximum single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.109 inches minimum single mounting facility single center group and 2.141 inches maximum single mounting facility single center group
-
Winding Operating Voltage
12.00 dc volts nominal single component 3rd secondary
-
Reliability Indicator
not established
-
Winding Operating Current
5.0 amperes dc maximum single component 3rd secondary
-
Thread Class (Non-Core)
err-070
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Maximum Operating Temp
130.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Body Height
3.624 inches minimum and 3.812 inches maximum
-
Winding Operating Voltage
46.00 dc volts nominal single component 2nd secondary
-
Transformer Winding Connection Type
delta-wye
-
Special Features
one primary winding; six secondary windings,all secondary voltage and current is after rectification
-
Nominal Thread Size
0.138 inches single group
-
Mounting Facility Quantity
4 single group