NSN: 5950-00-543-0347
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
11 standoff, solder lug and 1 tab, solder lug
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Voltage
117.00 ac volts nominal single component single primary
-
Body Length
2.937 inches minimum and 3.062 inches maximum
-
Winding Operating Voltage
5.00 ac volts nominal single component all secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.859 inches nominal single mounting facility single center group
-
Winding Operating Current
2.0 amperes ac maximum single component all secondary
-
Reliability Indicator
not established
-
Overall Height
4.562 inches minimum and 4.875 inches maximum
-
Mounting Facility Quantity
4 single group
-
Body Width
2.500 inches minimum and 2.625 inches maximum
-
Frequency Rating
50.0 hertz nominal single component or 60.0 hertz nominal single component
-
Nominal Thread Size
0.164 inches single group
-
Winding Tap Location (Non-Core)
err-070
-
Body Height
4.062 inches minimum and 4.250 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.297 inches nominal single mounting facility single center group
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Maximum Operating Temp
71.0 deg celsius