NSN: 5950-00-566-0063
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Height
2.312 inches minimum and 2.500 inches maximum
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Mounting Facility Quantity
2 single group
-
Maximum Operating Temp
90.0 deg celsius
-
Mounting Method
threaded stud single group
-
Body Width
2.250 inches minimum and 2.375 inches maximum
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary
-
Overall Height
2.875 inches minimum and 3.188 inches maximum
-
Winding Operating Voltage
6.40 ac volts nominal single component all secondary
-
Winding Operating Current
900.0 milliamperes ac maximum single component 1st secondary
-
Body Length
2.563 inches minimum and 2.688 inches maximum
-
Distance Between Mounting Facility Centers
1.250 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Quantity Per Inch
24 single group
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
6 standoff, wire lead
-
Nominal Thread Size
0.190 inches single group
-
Winding Operating Current
8.6 amperes ac maximum single component 2nd secondary