NSN: 5950-00-581-9274
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
15 tab,solder lug
-
Special Features
case metal material
-
Winding Operating Voltage
800.00 ac volts nominal
-
Winding Operating Voltage
6.30 ac volts nominal
-
Winding Operating Current
90.0 milliamperes dc maximum
-
Winding Operating Current
2.5 amperes dc maximum
-
Winding Operating Current
2.0 amperes dc maximum
-
Winding Tap Location
center tap
-
Winding Function And Quantity
1 primary and 4 secondary
-
Body Height
4.875 inches nominal
-
Body Length
3.562 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.109 inches minimum and 2.141 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.609 inches minimum and 2.641 inches maximum
-
Winding Operating Voltage
5.00 ac volts nominal
-
Winding Operating Voltage
110.00 ac volts nominal and 115.00 ac volts nominal and 120.00 ac volts nominal and 125.00 ac volts nominal
-
Winding Tap Location
multiple taps w/o center tap
-
Mounting Method
threaded stud
-
Mounting Facility Quantity
4
-
Inclosure Type
hermetically sealed
-
Body Width
3.062 inches nominal
-
Winding Shielding Method
internal shield grounded to inclosure and core
-
Input-Output Phase Relationship
single phase to single phase
-
Frequency Rating
54.0 hertz minimum and 66.0 hertz maximum