NSN: 5950-00-645-4767
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Current
2.5 amperes ac maximum single component single secondary
-
Winding Operating Voltage
120.00 ac volts nominal single component single secondary
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal single mounting facility single center group
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Overall Height
4.672 inches nominal
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Height
4.047 inches nominal
-
Winding Operating Voltage
208.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
5 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.875 inches nominal single mounting facility single center group
-
Body Width
2.297 inches nominal
-
Reliability Indicator
not established
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Quantity Per Inch
24 single group
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Nominal Thread Size
0.190 inches single group
-
Body Length
3.672 inches nominal