NSN: 5950-00-706-8728
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.750 inches nominal single mounting facility single center group
-
Cubic Measure (Non-Core)
43.1 cubic inches
-
Body Length
3.490 inches minimum and 3.510 inches maximum
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Thread Series Designator
unf single group
-
Winding Operating Voltage
46.00 ac volts nominal single component 3rd secondary
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
68.00 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
46.00 ac volts nominal single component 4th secondary
-
Body Width
2.865 inches minimum and 2.885 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Winding Operating Voltage
68.00 ac volts nominal single component 2nd secondary
-
Winding Operating Current
600.0 milliamperes ac maximum single component all secondary
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Function And Quantity
1 primary single component and 9 secondary single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Height
4.240 inches minimum and 4.260 inches maximum
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
30 wire lead
-
Nominal Thread Size
0.190 inches single group
-
Thread Direction (Non-Core)
err-070