NSN: 5950-00-762-8831
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Width
4.000 inches nominal single mounting facility single center group
-
Body Length
4.940 inches minimum and 5.015 inches maximum
-
Inclosure Type
hermetically sealed
-
Winding Function And Quantity
1 primary and 4 secondary single component
-
Thread Quantity Per Inch
20 single group
-
Winding Operating Current
3.7 amperes ac maximum single component single primary
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
12 solder stud
-
Reference Number Differentiating Characteristics
material will be in accordance with ships parts control center activity hx quality control,manufacturing and testing specifications
-
Body Width
4.940 inches minimum and 5.015 inches maximum
-
Body Height
4.026 inches minimum and 4.031 inches maximum
-
Mounting Facility Quantity
4 single group
-
Mounting Method
threaded stud single group
-
Nominal Thread Size
0.250 inches single group
-
(Non-Core Data) Winding Tap Location
multiple taps w/o center tap single component single primary
-
Winding Operating Current
0.1 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
0.3 amperes ac maximum single component 2nd secondary
-
Winding Operating Current
1.2 amperes ac maximum single component 1st secondary
-
Winding Operating Current
5.0 amperes ac maximum single component 4th secondary
-
Criticality Code Justification
zzzy
-
Design Control Reference
108873gp1
-
Manufacturers Code
94271
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component