NSN: 5950-00-775-9382
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.562 inches maximum
-
Mounting Facility Quantity
4 single group
-
Maximum Operating Temp
65.0 deg celsius
-
Winding Operating Current
150.0 milliamperes ac maximum single component 2nd secondary
-
Terminal Type And Quantity
11 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.000 inches nominal single mounting facility single center group
-
Inclosure Type
open
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Winding Operating Voltage
64.00 ac volts nominal single component 3rd secondary
-
Mounting Slot Width
0.203 inches nominal single group
-
Winding Operating Voltage
46.00 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
16.00 ac volts nominal single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Operating Current
3.8 amperes ac maximum single component 1st secondary
-
Overall Width
2.375 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Frequency Rating
60.0 hertz nominal single component
-
Body Height
3.062 inches maximum
-
Mounting Method
flange single group and slot single group
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Current
320.0 milliamperes ac maximum single component 3rd secondary