NSN: 5950-00-809-4758
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Body Width
2.500 inches nominal
-
Winding Operating Current
5.0 amperes ac maximum single component single secondary
-
Winding Operating Voltage
416.00 ac volts nominal single component single primary
-
Mounting Method
threaded stud single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Height
4.313 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
-
Maximum Operating Temp
85.0 deg celsius
-
Frequency Rating
400.0 hertz nominal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Quantity Per Inch
24 single group
-
Body Length
3.625 inches nominal
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Nominal Thread Size
0.190 inches single group
-
Terminal Type And Quantity
4 turret
-
Winding Operating Voltage
115.00 ac volts nominal single component single secondary
-
Overall Height
4.844 inches nominal