NSN: 5950-00-967-2092
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Frequency Rating
50.0 hertz minimum single component and 400.0 hertz maximum single component
-
Winding Operating Current
600.0 milliamperes ac maximum single component 2nd secondary
-
Body Length
2.250 inches nominal
-
Winding Function And Quantity
2 primary single component and 2 secondary single component
-
Winding Operating Voltage
120.00 ac volts nominal single component 1st primary
-
Mounting Method
threaded stud single group
-
Nominal Thread Size
0.138 inches single group
-
Thread Quantity Per Inch
32 single group
-
Terminal Type And Quantity
9 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.438 inches nominal single mounting facility single center group
-
Inclosure Type
fully inclosed
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.688 inches nominal single mounting facility single center group
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary
-
Reliability Indicator
not established
-
Winding Operating Current
40.0 milliamperes ac maximum single component 1st secondary
-
Body Height
2.060 inches nominal
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
58.00 ac volts nominal single component 1st secondary
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Width
2.000 inches nominal
-
Thread Series Designator
unc single group
-
Winding Operating Voltage
240.00 ac volts nominal single component 2nd primary
-
Thread Direction (Non-Core)
err-070