Technical Characteristics
-
Frequency Rating
50.0 hertz minimum and 1000.0 hertz maximum single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Width
3.438 inches maximum
-
Body Height
4.375 inches nominal
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4 single group
-
Winding Tap Location
center tap single component 1st secondary
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.250 inches nominal single mounting facility single center group
-
~1
nter group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.453 inches minimum and 2.547 inches maximum single mounting facility single ce
-
Mounting Slot Width
0.218 inches nominal single group
-
Body Length
3.625 inches maximum
-
Maximum Operating Temp
125.0 deg celsius
-
Mounting Method
slot single group
-
Winding Function And Quantity
1 primary and 5 secondary single component
-
Winding Operating Current
2.5 amperes ac nominal single component 4th secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
1180.00 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
-
Terminal Type And Quantity
14 tab, solder lug
-
Winding Operating Current
1.5 amperes ac nominal single component 2nd secondary
-
Winding Operating Current
2.0 amperes ac nominal single component 3rd secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 4th secondary
-
Unpackaged Unit Weight
10.000 pounds