NSN: 5950-00-987-1856
Coils and Transformers
TRANSFORMER,POWER AUTOTRANSFORMER
TRANSFORMER,POWER AUTOTRANSFORMER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
9 threaded stud
-
Winding Operating Voltage
274.00 ac volts minimum and 439.00 ac volts maximum single component single primary output
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary input
-
Mounting Method
unthreaded hole single group
-
Inclosure Type
fully inclosed
-
Input-Output Phase Relationship
single phase to single phase single component
-
Mounting Hole Diameter
0.218 inches minimum and 0.228 inches maximum single group
-
Overall Width
4.200 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.375 inches nominal single mounting facility single center group
-
Overall Length
4.250 inches maximum
-
Reliability Indicator
not established
-
(Non-Core Data) Unpackaged Unit Weight
7.700 pounds
-
Winding Power Rating
4.08 k1lovolt-amperes single component single primary output
-
Winding Operating Current
9.2 amperes ac nominal single component single primary output
-
(Non-Core Data) Winding Tap Location
multiple taps w/o center tap single component single primary input
-
(Non-Core Data) Cubic Measure
94.6 cubic inches
-
Winding Function And Quantity
1 primary, fixed autotransformer type single component
-
Mounting Facility Quantity
4 single group
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
-
Overall Height
5.300 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.125 inches nominal single mounting facility single center group
-
(Non-Core Data) Dummy Terminal Quantity
1