NSN: 5950-00-989-7956
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
225.00 ac volts nominal single component 1st secondary
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Nominal Thread Size
0.112 inches single group
-
Winding Operating Current
5.0 milliamperes ac maximum single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.500 inches nominal single mounting facility single center group
-
Winding Operating Voltage
815.00 ac volts nominal single component 2nd secondary
-
Winding Tap Location (Non-Core)
err-070
-
Thread Quantity Per Inch
40 single group
-
Mounting Method
threaded hole single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.375 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Body Length
2.125 inches maximum
-
Maximum Operating Temp
55.0 deg celsius
-
Body Height
2.500 inches maximum
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Current
1.5 amperes ac maximum single component 3rd secondary
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Winding Operating Current
20.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
-
Terminal Type And Quantity
10 tab, solder lug
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Body Width
1.875 inches maximum