NSN: 5950-01-011-9533
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.594 inches minimum single mounting facility single center group and 2.656 inches maximum single mounting facility single center group
-
Winding Operating Voltage
200.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
7 solder stud
-
Transformer Winding Connection Type
scott
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.094 inches minimum single mounting facility single center group and 2.156 inches maximum single mounting facility single center group
-
Nominal Thread Size
0.164 inches single group
-
Winding Tap Location (Non-Core)
err-070
-
Body Height
3.562 inches maximum
-
Overall Width
3.062 inches maximum
-
Mounting Method
threaded hole single group
-
Mounting Facility Quantity
4 single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Current
5.6 amperes ac nominal single component single secondary
-
Maximum Operating Temp
105.0 deg celsius
-
Winding Operating Voltage
45.00 ac volts nominal single component single secondary
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
three phase to two phase single component
-
Winding Power Rating
250.0 volts-amperes single component single secondary
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Thread Direction (Non-Core)
err-070