NSN: 5950-01-079-9037

Coils and Transformers

REACTOR

5950 - Coils and Transformers

REACTOR

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reliability Indicator

    not established

  • Inductance Rating

    500.00 microhenries nominal single component all winding

  • Winding Quantity

    2 single component

  • Inclosure Type

    fully inclosed

  • Mounting Facility Quantity

    1 single group

  • Winding Operating Current

    5.0 amperes dc maximum single component all winding

  • Dc Resistance Rating In Ohms

    0.047

  • Terminal Type And Quantity

    4 wire lead

  • Turn Quantity

    52 single component all winding

  • Mounting Hole Diameter

    0.252 inches nominal single group

  • Frequency Rating

    400.0 hertz nominal single component

  • Body Length

    0.700 inches maximum

  • Body Outside Diameter

    1.600 inches maximum

  • Mounting Method

    unthreaded hole single group

  • Rating Method

    winding turns and electrical single component all winding

  • Winding Conductor Size

    0.03589 inches american wire gage single component all winding

Certified to
AS6081 Methods

Implementing Quality Procurement