NSN: 5950-01-100-0718
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
19.0 kilohertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Maximum Transformer Power Rating
86.5 volt-ampere single component
-
Body Outside Diameter
1.906 inches maximum
-
Inclosure Type
fully inclosed
-
Winding Tap Location
center tap single component 2nd secondary
-
Winding Tap Location
center tap single component single primary
-
Winding Operating Current
290.0 milliamperes ac nominal single component 2nd secondary
-
Reliability Indicator
not established
-
Body Length
0.750 inches maximum
-
Iii Maximum Operating Temp
130.0 deg celsius
-
Winding Operating Voltage
29.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
18 wire lead
-
Mounting Method
terminal single group
-
Winding Function And Quantity
1 primary and 3 secondary single component
-
Features Provided
tinned wire leads
-
Winding Tap Location
multiple taps w/center tap single component 1st secondary
-
Winding Tap Location
multiple taps w/center tap single component 3rd secondary
-
Winding Operating Current
240.0 milliamperes ac maximum single component 3rd secondary
-
Winding Operating Current
420.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Voltage
12.30 ac volts nominal and 38.66 ac volts nominal and 50.96 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
6.59 ac volts nominal and 7.47 ac volts nominal and 20.65 ac volts nominal and 21.53 ac volts nominal and 28.12 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
72.06 ac volts nominal single component 2nd secondary