NSN: 5950-01-128-3751
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.609 inches minimum single mounting facility single center group and 2.641 inches maximum
-
Overall Width
2.937 inches minimum and 3.062 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Shielding Method
internal shield grounded to core single component
-
Maximum Operating Temp
130.0 deg celsius
-
Mounting Facility Quantity
4 single group
-
Winding Function And Quantity
1 primary single component and 2 secondary
-
Winding Operating Current
2.32 amperes ac nominal single component all secondary
-
Winding Power Rating
139.2 volts-amperes single component all secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
6 wire hook
-
Thread Class
2a single group
-
Thread Direction
right-hand single group
-
Reliability Indicator
not established
-
Overall Length
3.437 inches minimum and 3.562 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.109 inches minimum single mounting facility single center group and 2.141 inches maximum
-
Overall Height
5.000 inches minimum and 5.250 inches maximum
-
Frequency Rating
50.0 hertz minimum single component and 65.0 hertz maximum
-
Inclosure Type
hermetically sealed
-
Mounting Method
threaded stud single group
-
Cubic Measure
57.3 cubic inches
-
Nominal Thread Size
0.164 inches single group
-
Winding Operating Voltage
60.00 ac volts nominal single component all secondary
-
Unpackaged Unit Weight
7.400 pounds