NSN: 5950-01-146-2937
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Direction
right-hand single group
-
Dummy Terminal Quantity
2
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.555 inches maximum single mounting facility single center group
-
Frequency Rating
12.5 kilohertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Length
1.880 inches maximum
-
Body Width
1.880 inches maximum
-
Body Height
2.750 inches maximum
-
Maximum Operating Temp
85.0 deg celsius
-
Inclosure Type
fully inclosed
-
Mounting Method
threaded hole single group
-
Nominal Thread Size
0.112 inches single group
-
Winding Operating Current
160.0 milliamperes ac maximum single component 4th secondary
-
Winding Operating Current
2.0 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
8.9 amperes ac maximum single component 1st secondary
-
Winding Operating Voltage
118.90 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
31.90 ac volts nominal single component 2nd primary
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
18 turret
-
Winding Operating Current
10.0 milliamperes ac maximum single component 2nd primary
-
Winding Operating Current
2.0 amperes ac maximum single component 2nd secondary
-
Winding Operating Voltage
158.80 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
23.70 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
63.50 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
88.00 ac volts nominal single component 1st primary
-
Thread Class
2b single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.555 inches maximum single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Winding Function And Quantity
2 primary and 4 secondary single component
-
Winding Tap Location
center tap single component all primary
-
Winding Tap Location
center tap single component all secondary