NSN: 5950-01-155-4861
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
2.0 amperes ac maximum single component single secondary
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
18.50 ac volts nominal single component single secondary
-
Winding Shielding Method
core grounded and brought out to terminal single component and external inclosure connected to terminal single component
-
Terminal Type And Quantity
9 wire hook
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Power Rating
37.0 volts-amperes single component single secondary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Height
2.000 inches nominal
-
Input-Output Phase Relationship
three phase to three phase single component
-
Body Length
3.000 inches nominal
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Overall Length
4.000 inches nominal
-
Maximum Operating Temp
130.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.625 inches nominal single mounting facility single center group
-
Body Width
2.000 inches nominal
-
Inclosure Type
hermetically sealed
-
Transformer Winding Connection Type
delta-wye
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.625 inches nominal single mounting facility single center group
-
Mounting Hole Diameter
0.219 inches nominal single group