NSN: 5950-01-179-0395
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
25.60 ac volts minimum single component 1st secondary and 26.40 ac volts maximum single component 1st secondary
-
Body Width
1.552 inches minimum and 1.572 inches maximum
-
Criticality Code Justification
feat
-
Mounting Facility Quantity
2 single group
-
Distance Between Mounting Facility Centers
1.240 inches minimum single mounting facility single center group and 1.260 inches maximum single mounting facility single center group
-
Special Features
weapon system essential
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Maximum Operating Temp
100.0 deg celsius
-
Inclosure Type
fully inclosed
-
Terminal Type And Quantity
7 tab, solder lug
-
Winding Operating Current
8.0 milliamperes ac nominal single component 2nd secondary
-
Mounting Method
unthreaded hole single group
-
Winding Operating Current
1.3 amperes ac nominal single component 1st secondary
-
Reliability Indicator
not established
-
Body Height
1.380 inches maximum
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Power Rating
0.032 volts-amperes single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
3.80 ac volts minimum single component 2nd secondary and 4.20 ac volts maximum single component 2nd secondary
-
Overall Length
2.000 inches maximum
-
Winding Power Rating
33.8 volts-amperes single component 1st secondary
-
Mounting Hole Diameter
0.115 inches minimum single group and 0.135 inches maximum single group
-
Cooling Method
self-cooled
-
Specification/Standard Data
78711-t235a284 manufacturers source control