NSN: 5950-01-251-4307
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
0.645 inches maximum
-
Frequency Rating
12.8 kilohertz nominal single component
-
Winding Operating Voltage
2.00 ac volts nominal single component 1st secondary
-
Features Provided
tinned wire leads
-
Winding Operating Current
5.0 milliamperes ac maximum single component single primary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
5.00 ac volts nominal single component single primary
-
Maximum Operating Temp
85.0 deg celsius
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Unpackaged Unit Weight (Non-Core)
20.0 grams
-
Terminal Type And Quantity
8 wire lead
-
Body Outside Diameter
0.500 inches nominal
-
Winding Operating Voltage
666.00 ac volts nominal single component 2nd secondary