NSN: 5950-01-267-3977
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Features Provided
color coded lead
-
Reliability Indicator
not established
-
Coil Form Type
solid single component
-
Mounting Method
terminal single group
-
Winding Conductor Size
0.02535 inches american wire gage single component 3rd secondary
-
Body Width
2.470 inches nominal
-
Winding Conductor Size
0.04030 inches american wire gage single component 1st primary
-
Turn Quantity
1 single component 3rd secondary
-
End Item Identification
power supply pp-6224b/u
-
Winding Conductor Size
0.02535 inches american wire gage single component 4th secondary
-
Body Height
2.560 inches nominal
-
Turn Quantity
1 single component 4th secondary
-
Rating Method
winding turns single component 3rd secondary
-
Rating Method
winding turns single component 4th secondary
-
Winding Function And Quantity
2 primary single component and 4 secondary single component
-
Winding Tap Location (Non-Core)
center tap single component 2nd primary
-
Terminal Type And Quantity
14 wire lead
-
Rating Method
winding turns single component all primary
-
Rating Method
winding turns single component 1st secondary
-
Turn Quantity
3 single component 1st secondary
-
Body Length
2.800 inches nominal
-
Turn Quantity
21 single component 1st primary
-
Turn Quantity
6 single component 2nd primary
-
Inclosure Type
fully inclosed
-
Winding Conductor Size
0.02535 inches american wire gage single component 1st secondary
-
Turn Quantity
4 single component 2nd secondary
-
Winding Conductor Size
0.02535 inches american wire gage single component 2nd primary