NSN: 5950-01-271-1747
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary, fixed autotransformer type single component
-
Inclosure Type
open
-
Body Outside Diameter
0.155 inches nominal
-
Coil Form Type
air wound single component
-
Turn Quantity
2-1/4 single component single primary input
-
Turn Quantity
5 single component single primary output
-
Winding Conductor Size
0.01594 inches american wire gage single component single primary input
-
Winding Conductor Size
0.01594 inches american wire gage single component single primary output
-
Rating Method
winding turns single component single primary input
-
Maximum Operating Temp
125.0 deg celsius
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Rating Method
winding turns single component single primary output
-
Terminal Type And Quantity
3 wire lead
-
Features Provided
left hand wound coil and tinned wire leads