NSN: 5950-01-345-5593
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Operating Temp
155.0 deg celsius
-
Features Provided
tinned wire leads
-
Body Height
0.680 inches maximum
-
Winding Conductor Size
0.05082 inches american wire gage single component 3rd secondary
-
Rating Method
electrical single component single primary and winding turns single component all secondary
-
Overall Width
1.125 inches nominal
-
Turn Quantity
2 single component 3rd secondary
-
Winding Conductor Size
0.01594 inches american wire gage single component single primary
-
Turn Quantity
8 single component 2nd secondary
-
Turn Quantity
40 single component single primary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Rating Method
winding turns single component single primary
-
Turn Quantity
8 single component 1st secondary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Test Data Document
80063-a3034805 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Frequency Rating
20.0 kilohertz nominal single component
-
Winding Conductor Size
0.01790 inches american wire gage single component 2nd secondary
-
Mounting Method
terminal single group
-
Coil Form Type
solid single component
-
Overall Length
1.185 inches nominal
-
Reliability Indicator
not established
-
Winding Conductor Size
0.01790 inches american wire gage single component 1st secondary
-
Terminal Type And Quantity
9 wire lead
-
Inclosure Type
fully inclosed
-
Inductance Rating
5.80 millihenries nominal single component single primary