NSN: 5950-01-347-1847
Coils and Transformers
TRANSFORMER,PULSE
TRANSFORMER,PULSE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Pulse Duration In Microseconds (Non-Core)
0.050 single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
0.500 inches nominal single mounting facility single center group
-
Pulse Rise Time In Microseconds (Non-Core)
0.050 single component
-
Test Data Document
99187-5905468 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Hazardous Locations/Environmental Protection
vibration resistant
-
Body Height
0.275 inches maximum
-
Inductance Rating
6.00 microhenries maximum single component single secondary
-
Impedance Rating In Ohms
3000.0 minimum single component single primary
-
Frequency Rating
250.0 hertz minimum single component and 3.0 kilohertz maximum single component
-
Inclosure Type
fully inclosed
-
Overall Width
0.630 inches maximum
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inductance Rating
7.50 millihenries minimum single component single primary
-
Cubic Measure (Non-Core)
0.1091475 cubic inches
-
Terminal Type And Quantity
8 pin
-
Winding Operating Voltage
21.21 ac pounds per hour wet single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.400 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Pulse Decay Time In Microseconds (Non-Core)
0.025 single component
-
Inclosure Material (Non-Core)
rubber
-
Maximum Operating Temp
130.0 deg celsius
-
Dc Resistance Rating In Ohms
1.500 single component single primary
-
Overall Length
0.630 inches maximum
-
Dc Resistance Rating In Ohms
1.500 single component single secondary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Winding Operating Current
60.0 milliamperes nominal b and better drop siding single component single primary
-
Unpackaged Unit Weight (Non-Core)
1.000 ounces
-
Peak Voltage Rating (Non-Core)
60.0 volts single component single primary
-
Winding Tap Location (Non-Core)
multiple taps w/center tap single component single secondary
-
Primary To Secondary Turn Ratio
1.4 to 1 single component