NSN: 5950-01-371-3153

Coils and Transformers

TRANSFORMER,POWER

5950 - Coils and Transformers

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Function And Quantity

    2 primary single component and 2 secondary single component

  • Body Length

    0.465 inches maximum

  • Features Provided

    tinned wire leads

  • Winding Operating Voltage

    11.31 ac volts nominal single component all secondary

  • Body Outside Diameter

    0.700 inches maximum

  • Inclosure Type

    fully inclosed

  • Frequency Rating

    100.0 kilohertz nominal single component

  • Reliability Indicator

    not established

  • Mounting Method

    terminal single group

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Current

    23.33 milliamperes ac nominal single component all primary

  • Maximum Operating Temp

    130.0 deg celsius

  • Terminal Type And Quantity

    8 wire lead

  • Winding Operating Current

    98.27 milliamperes ac nominal single component all secondary

  • Winding Operating Voltage

    46.37 ac volts nominal single component all primary