NSN: 5950-01-381-5223
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
16 tab w/screw
-
Winding Function And Quantity
2 primary single component and 4 secondary single component
-
Frequency Rating
50.0 hertz nominal single component or 60.0 hertz nominal single component
-
Body Width
2.500 inches nominal
-
Winding Shielding Method
primary and secondary shielded and brought out to terminal single component
-
Maximum Transformer Power Rating
200.0 watts single component
-
Winding Operating Current
0.1 amperes nominal b single component 2nd secondary
-
Body Height
4.000 inches maximum
-
Winding Operating Current
0.1 amperes nominal b single component 4th secondary
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
32.00 ac pounds per hour wet single component 1st secondary
-
Winding Operating Voltage
16.50 ac pounds per hour wet single component 2nd secondary
-
Winding Operating Voltage
16.50 ac pounds per hour wet single component 4th secondary
-
Winding Operating Voltage
115.00 ac pounds per hour wet single component all primary
-
Reliability Indicator
not established
-
Winding Operating Voltage
32.00 ac pounds per hour wet single component 3rd secondary
-
Body Length
4.250 inches nominal
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Current
7.5 amperes nominal b single component 1st secondary
-
Winding Operating Current
3.2 amperes nominal b single component all primary
-
Winding Operating Current
7.5 amperes nominal b single component 3rd secondary